8-1-9 Defect Diagnosis Function
1. Defect diagnosis functions are easy SVC when defects occur which can affect product performance.
2. When a defect occurs, the buttons will not operate; but the tones. such as "ding". will sound.
3. When the defect CODE removes the sign, it returns to normal operation (RESET).
4. The defect CODE shows on the refrigerator DISPLAY as temperature LED, and the other LED turns off.
-Show ERROR CODE on Refrigerator Temperature Panel and Freezer Temperature panel.
ERROR CODE on Freezer Temperature panel
Defect code signs
Defect code signs
FREEZER
COLDER WARMER
°
F/
°
C
0
°
F IS RECOMMENDED
TEMPERATURE
REFRIGERATOR
LOCK
COLDER WARMER
HOLD 3 SECONDS
37
°
F IS RECOMMENDED
TEMPERATURE
NO
ITEM
ERROR CODE
CONTENTS
REMARKS
REF. TEMP. PANEL
FRZ. TEMP. PANEL
1
2
3
4
5
Freezer sensor
malfunctions
Refrigerator
sensor
malfunctions
Defrost sensor
malfunctions
Room
Temperature
sensor
malfunctions
Defrosting
malfunctions
On LED CHECK mode
ERROR CODE sign
Er
Er
Er
Er
Er
FS
rS
dS
rT
dH
Open or short-circuited wire
Open or short-circuited wire
Open or short-circuited wire
Open or short-circuited wire
2 hours after defrosting
starts, the sensor is not
above 50°F(10°C)
*
Inspect
connecting wires
on each sensor
Temperature FUSE cuts off,
HEATER cuts off, DRAIN is
clogged, HEATER starts,
RELAY malfunctions
NO
ITEM
DEFECT SIGNS
CONTENTS
REMARKS
F1 F2 F3 F4 F5 F6 F7
1
2
3
4
5
Freezer sensor
malfunctions
Refrigerator sensor
malfunctions
Defrost sensor
malfunctions
Room
Temperature
sensor
malfunctions
Defrosting
malfunctions
On LED CHECK mode
Open or short-circuited wire
Open or short-circuited wire
Open or short-circuited wire
Open or short-circuited wire
2 hours after
defrosting starts,
the sensor is not
above 50°F(10°C)
*
Inspect
connecting wires
on each sensor
Temperature FUSE cuts off,
HEATER cuts off, DRAIN is
clogged, HEATER starts,
RELAY malfunctions
Defect code Panel
FREEZER
OFF
TEMPERATURE
1
2
3
4
5
6
7
REFRIGERATOR
LOCK
ADJUST
HOLD 3 SECONDS
4 IS RECOMMENDED
TEMPERATURE
WARMER
COLDER
1
2
3
4
5
6
7
ADJUST
4 IS RECOMMENDED
WARMER
COLDER
:ON :OFF