7-2 CONTROL METHOD ACCORDING TO FUNCTIONS
7-2-1 Start Position
1. After POWER OFF or Power Cut, check EJECTOR's position with MICOM initialization to restart.
2. Control Method to check if it's in place:
(1) EJECTOR is in place,
- The ejector must be in the park position before a new cycle can be initiated.
(2) EJECTOR isn't in place:
A. If there is no ice formed in the ice maker, it should take approximately 2 minutes for the ejector blades to cycle through
the harvest mode and return to the park position.
B. If there is ice formed in the ice maker, it can take up to 18 minutes for the ejector blades to cycle through the
harvest mode and return to the park position.
7-2-2 Ice Making Mode
1. The Ice Making Mode starts once the ejector is in the park position and the ice maker mold is filled with water.
2. The Ice Making Mode is terminated when the ice maker sensor reaches 19°F(-7°C). This may take between 1 and 4
hours.
7-2-3 Harvest Mode
1. The Harves mode is initiated when the temperature is satisfied with the shut-off arm in the down position.
2. Once the Harvest mode is initiated, the heater is operated for 30 seconds.
3. After 30 seconds, the ejector blades are operated. (Pin 10 of micom from the hall sensor will read 5V.)
4. Once the ejector blades have reached the park position and the hall sensor is reading 0V, water fill will be initiated.
NOTE :
If no movement is detected from the shut-off arm (detect lever), that a Harvest mode will be attempted every 2
hours.
- 18 -
Heater
on
off
on
0V
5V
off
30 sec.
10 sec.
Motor
Hall IC
Harvest mode
end poing
2 ms
Ice-making sensor temperature is 50
°
F(10˚C) or more
Max. 18 minutes
After detect LEVER rises
<fig1. Harvest mode process>