TROUBLE DIAGNOSIS
- 64 -
CLAIMS.
CAUSES AND CHECK POINTS.
HOW TO CHECK
3. Refrigeration
is weak.
4) No cooling air circulation.
5) Compressor capacity.
6) Refrigerant
too much or too little.
7) Continuous operation
- No contact of temperature controller. - Foreign materials.
8) Damper opens continuously.
Foreign materials
jammed.
Failed sensor. - Position of sensor.
Characteristics
of damper.
9) Food storing place. - Near the outlet of cooling air.
Faulty fan motor.
Small cooling air
discharge.
Fan is
constrained.
Insufficient
motor RPM
Faulty fan.
Shorud. Bent.
Ice and foreign materials on rotating parts.
Fan shroud contact. - Clearance.
Damping evaporator contact.
Accumulated residual frost.
Fan misuse.
Bad shape.
Loose connection. - Not tightly connected.
Insert depth.
Rating misuse.
Small capacity.
Low valtage.
Malfunction of charging cylinder.
Wrong setting of refrigerant.
Insufficient compressor. - Faulty compressor.
Fan overload. - Fan misuse.
Bad low termperature RPM characteristics.
Rated power misuse.
Low voltage.
P/U liquid dump.
EPS water sediment.
Screw.
Bad characteristics of its own temperatue.
Parts misuse.
Charge of temperature - Impact.
characteristics.
■
Check visually after
disassembly.
■
Check visually after
disassembly.
Содержание LRSPC2031BS
Страница 46: ...1 GR P247 GR P207 GR L247 GR L207 MICOM CIRCUIT DESCRIPTION 46 GR L247 207 GR P247 207 WORK ...
Страница 47: ...2 GR C247 GR C207 GR B247 GR B207 GR B197 MICOM CIRCUIT DESCRIPTION 47 JCR1 JCR2 JCR3 JCR4 ...
Страница 49: ...MICOM CIRCUIT DESCRIPTION 49 Freezer Temp Control Refrigerator Temp Control Crushed Water Cube ...
Страница 51: ...MICOM CIRCUIT DESCRIPTION 51 Freezer Temp Control Refrigerator Temp Control ...
Страница 58: ...CIRCUIT 58 GR B247 GR B207 GR C247 GR C207 GR B197 ...
Страница 113: ...P No 3828JD8456H APR 2002 Printed in Korea ...