3. When customer uses bottled water.
*If customer wants to use bottled water, extra pump should be installed as shown below.
1. The pump system should not be on the floor (it may cause noise and vibration). Securely fasten the inlet and outlet
nuts of pump.
2. If there is any leakage after installation, cut the water tube at right angle and reassemble.
3. When put the water tube end into the bottle, leave a clearance between bottle bottom and water tube end.
4 Check water coming out and any leakage.
Caution : • If feed tube is more than 4m, less water will come out due to pressure drops.
• Use standard feed tube to prevent leaking.
■
Outternal Filter
1. Filter Fixation
1) Connect feed tube to the filter outlet and water valve connecting tube.
2) Fix the filter at proper place around the sink where it is easy to replace the filter and to receive the cleaning water.
Please consider the length of tube shall be less than 12m when locating filter.
3) When fixing the filter, use fixing plate and cable depending on the surrounding conditions.
2. Filter Cleaning
1) Connect feed tube to the inlet of feed valve and filter.
2) Clean the main valve and feed valve with water for at
least one minute until clean water comes out.
HOW TO INSTALL REFRIGERATOR
- 21 -
Water Tube
Nut
Inlet
Outlet
Fixing Plate
Fixing Plate
Fixing Cable
Water
Filter
Filter Inlet
Feed Valve
Hot Water
Cold Water
Содержание LRSPC2031BS
Страница 46: ...1 GR P247 GR P207 GR L247 GR L207 MICOM CIRCUIT DESCRIPTION 46 GR L247 207 GR P247 207 WORK ...
Страница 47: ...2 GR C247 GR C207 GR B247 GR B207 GR B197 MICOM CIRCUIT DESCRIPTION 47 JCR1 JCR2 JCR3 JCR4 ...
Страница 49: ...MICOM CIRCUIT DESCRIPTION 49 Freezer Temp Control Refrigerator Temp Control Crushed Water Cube ...
Страница 51: ...MICOM CIRCUIT DESCRIPTION 51 Freezer Temp Control Refrigerator Temp Control ...
Страница 58: ...CIRCUIT 58 GR B247 GR B207 GR C247 GR C207 GR B197 ...
Страница 113: ...P No 3828JD8456H APR 2002 Printed in Korea ...