2-5 Test Function
1. It is to force the operation during operation test, service, and cleaning. The test switch is mounted under the automatic
ice maker. The test function starts when the test switch is pressed for more than 0.5 second.
2. Test button does not work during ice ejection and water supply. It works when it is in the horizontal conditions. If mould is
full of ice during test function operation, ice ejection control and water supply control do not work.
3. When test switch is pressed for more than 0.5 second in the horizontal conditions, ice ejection starts irrespect of the
mould conditions. Water shall be splashed if test switch is pressed before the water in the mould freezes. Water shall be
supplied while the mould returns to the horizontal conditions after ice ejection. Therefore the problems of ice ejection,
returning to the horizontal conditions, and water supply can be checked by test switch. When test function performs
normally, buzzer sounds and water supply shall carry out. Check it for repair if buzzer does not sound.
4. When water supply is completed, the cycle operates normally as follows: Ice making
→
Ice ejection
→
Returning to
horizontal conditions
→
Water supply
5. Remove ice from the ice maker cube mould and press test switch when ice maker cube mould is full of ice as ice ejection
and water supply control do not work when cube mould is full of ice.
2-6. Other functions relating to freezer compartment door opening
1. When freezer door is open, ice dispenser stops in order to reduce noise and ice drop.
2. When freezer door is open during ice ejection and cube mould returning to horizontal condition, ice ejection and cube
mould level return proceed.
3. When freezer door is open, geared motor and cube ice solenoid immediately stop and duct door solenoid stops after 5
seconds.
4. Water dispenser stops in order to protect water drop when freezer door is open.
5. Test function operates normally irrespect of refrigearator compartment door opening.
ICE MAKER AND DISPENSER WORKING PRINCIPLES AND REPAIR
- 55 -
Содержание LRSPC2031BS
Страница 46: ...1 GR P247 GR P207 GR L247 GR L207 MICOM CIRCUIT DESCRIPTION 46 GR L247 207 GR P247 207 WORK ...
Страница 47: ...2 GR C247 GR C207 GR B247 GR B207 GR B197 MICOM CIRCUIT DESCRIPTION 47 JCR1 JCR2 JCR3 JCR4 ...
Страница 49: ...MICOM CIRCUIT DESCRIPTION 49 Freezer Temp Control Refrigerator Temp Control Crushed Water Cube ...
Страница 51: ...MICOM CIRCUIT DESCRIPTION 51 Freezer Temp Control Refrigerator Temp Control ...
Страница 58: ...CIRCUIT 58 GR B247 GR B207 GR C247 GR C207 GR B197 ...
Страница 113: ...P No 3828JD8456H APR 2002 Printed in Korea ...