4. Ice Maker Circuits
The above ice maker circuits are applied to GR-P247, GR-P207 and GR-L247, GR-L207 and composed of ice maker unit in
the freezer and ice maker driving part of main PWB. Water is supplied to the ice maker cube mould through the solenoid
relay for ice valve of solenoid valve in the machine room by opening valve for the set time. Water supply automatically stops
when water supply time is elapsed. This circuit is to realize the functions such as ice ejection of ice maker cube mould, ice
full detection, leveling, ice making temperature detection, etc. Refer to the temperature detecting circuits of Main PWB for
ice making temperature detection. Ice maker test switch input detection is the same as the door switch input detection circuit
of main PWB.
1. It is to force to operate during operation test, service, and cleaning. The test switch is mounted under the automatic ice
maker. The test function starts when the test switch is pressed for more than 0.5 second.
2. Test button does not work during ice ejection and water supply. It works when it is in the horizontal conditions. If cube
mould is full of ice during test function operation, ice ejection control and water supply control do not work.
3. Ice ejection carries out irrespect of ice formation in the ice making tray if test switch is pressed for more than 0.5 second.
Water shall be splashed if test switch is pressed before the water in the mould is completely frozen. Water shall be
supplied while the mould returns to the horizontal conditions after ice ejection. Therefore the problems of ice ejection,
leveling, and water supply can be checked by test switch. When test function performs normally, buzzer sounds and
water supply shall carry out. Check it for repair if buzzer does not sound.
4. When water supply is completed, normal cycle works: Ice Making
→
Ice Ejection
→
Level Return
→
Water Supply.
5. If ice maker stop switch is set to ON, normal cycle operates: Ice Making
→
Ice Ejection
→
Level Return
→
Water Supply.
If it is set to OFF, ice making conducts but ice ejection, level return, and water supply do not work.
ICE MAKER AND DISPENSER WORKING PRINCIPLES AND REPAIR
- 57 -
FOWARD
REVERSE
ICE MAKER
STOP SWITCH
Содержание LRSPC2031BS
Страница 46: ...1 GR P247 GR P207 GR L247 GR L207 MICOM CIRCUIT DESCRIPTION 46 GR L247 207 GR P247 207 WORK ...
Страница 47: ...2 GR C247 GR C207 GR B247 GR B207 GR B197 MICOM CIRCUIT DESCRIPTION 47 JCR1 JCR2 JCR3 JCR4 ...
Страница 49: ...MICOM CIRCUIT DESCRIPTION 49 Freezer Temp Control Refrigerator Temp Control Crushed Water Cube ...
Страница 51: ...MICOM CIRCUIT DESCRIPTION 51 Freezer Temp Control Refrigerator Temp Control ...
Страница 58: ...CIRCUIT 58 GR B247 GR B207 GR C247 GR C207 GR B197 ...
Страница 113: ...P No 3828JD8456H APR 2002 Printed in Korea ...