7-
Symptom
Check Point
1. Freezer room lamp
doesn’t work
1. Check the freezer door switch
2. Check the door S/W resistance
3. Check the LED Lamp
Resistance [
Ω
]
Door S/W
Normal
0
Open
Infinity
Voltage [V]
CON7
7th pin ~ 8th Pin
11.4~12.6V
LED Lamp
Voltage [V]
White & Yellow
Closed
0~2V
Open
11.4~12.6V
8-18. Freezer lamp doesn’t work