7. IPM Fault Trip and LED Blinking 7 times (IPM Fault)
Blink
Blink
Blink
Blink Blink Blink Blink OFF
→
Purpose : Protection Over-Current by failure IPM(IPM short)
→
Cause : IPM Short and failure
→
Logic : After the Comp. Off every 20 seconds restart Comp.
LED 7
Blinks
Replace PCB
LED 7
Blinks
About 5min
Reset
Test
Mode
1 Input
LED 8
Blinks
Replace PCB
Reset
LED 8
Blinks
About 5min
Test
Mode
1 Input
Multi
Tester
8. Comp Tx Error Trip and LED Blinking 8 times (Communication Error)
C heck the PCB Output
→
Check output voltage from PCB to Compressor.
Blink
Blink
Blink Blink Blink Blink
OFF
→
Purpose : Detection communication error with the Micom of the refrigerator control.
→
Cause : Communication Error
→
Logic : Only LED blinking without the Comp. Off
(Comp. is operate command before communication error)
A-Inverter
→ To judge whether there is any issue with the PCB operation, check the PCB output voltage.
Normal: Voltage 80[V] or higher output at ((COMMON,POWER)
Blink
IPM Output check
-10
3
-