– 41 –
Remove the three ¼-in. hex-head screws
from the bottom of the manifold panel.
7.
Pull the manifold panel straight out from the
range.
8.
Protective Cover
Ignitor Switch
Screw Seal
Valve Seal
Caution:
Ensure the valve seal and the screw
seal are in place BEFORE installing the valve.
1/4-in. Hex-Head
Manifold Panel
To remove the manifold panel:
Remove the oven door. (See
Oven Door
Removal
.)
Remove the main top. (See
Main Top
Removal
.)
Remove the surface burner valve knobs by
pulling each knob straight out.
Remove the two ¼-in. hex-head screws that
attach the shield to the top right side of the
manifold panel.
Remove the 2 Phillips-head screws and the 2
guides from the main top.
Remove the 4 Phillips-head screws that hold
the front of the manifold panel to the gas
manifold.
1.
2.
3.
4.
5.
6.
Maintop Burner Valves
The maintop burner valves are located inside
the manifold panel and are attached to the gas
manifold by a single screw.
To remove the burner valve:
Remove the manifold panel. (See
Manifold
Panel
.)
Turn off the gas supply to the range.
Using a ½-in. open-end wrench disconnect
the burner inlet tube from the valve
Remove the ¼-in. hex-head screw that holds
the burner valve to the gas manifold. Lower
the valve from the gas manifold.
Remove the protective cover from the valve
stem.
Remove the ignitor switch from the valve.
(See
Ignitor Switches
.)
1.
2.
3.
4.
5.
6.