COMPONENT TEST
NOTE:
1. The most common cause for control failure is corrosion on connectors.
Therefore, disconnecting and reconnecting wires will be necessary throughout test procedures
2. ALL units in the first few days of use should be checked for mis-wiring or loose connections
1. All/tests/checks should be made with a VOM or DVM having a sensitivity of 20,000 ohms per-volt DC, or
greater.
2. Check all connections before replacing components, looking for broken or loose wires, Failed terminals, or
wires not pressed into connectors far enough.
3. Resistance checks must be made with power cord unplugged from outlet, and with wiring harness or
connectors disconnected.
Before testing any of components, perform the following checks:
WARNING
• Disconnect power supply cord from the outlet before servicing
• Replace all panels and parts before operating
• Reconnect all grounding devices after servicing
- Failure to do so can result in death or electrical shock
!
!
NOTE: Below Ω value were tested at room temperature (77F/25°C)
Components
Test procedures
Results
Micro Switch
Normal
: below 2Ω
Normal
: Infinite
NOTE: The Micro switch will be held for 13 seconds during lock or unlock.
ON position (Unlock position)
OFF position (Lock position)
Oven Sensor
1. Refer to page 3-13 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x 1000)
Normal: Approximately
1.09 kΩ ± 10%
If not replace
NOTE: Ω Value was
tested at room
temperature (77F/25˚C)