Only training and service purposes
Components
Test procedures
Results
Single surface units:
Left Rear(LR)
Right Rear(RR)
Element
1. Refer to page 3-6 for the servicing procedure
2. Set the Multiple meter scale to the R x 1
3. Disconnect wires from cook-top elements
4. Touch the ohmmeter test leads to the element
terminal and 1A.
The meter should indicate 46 Ω ± 10%
Normal: Approximately 46 Ω,
If not replace
Element
terminal
Element
terminal
1A
2A
5. Touch the ohmmeter test leads to limiter terminals
1B and 2B.
With the temperature below 150˚F, the meter
should indicate an open circuit(infinite).
With the temperature above 150˚F, the meter
should indicate continuity (0Ω).
Below 150˚F
→
open circuit(infinite).
Above 150˚F
→
continuity (0 Ω)
Element
terminal
Element
terminal
1B
2B