- 41 -
9-6 Poor cooling in Fresh food section
No
1
Checking flow
Check the sensor resistance.
2
Reset the unit and
Input Test 1 Mode.
(Push the button 1 time)
3
Check If cold air blows from air vent with
your hand.
The sensor is determined by
the temperature.
For example, 30
indicates 32°F.
Result & SVC Action
<CON7>
Temperature
23°F
°C
32°F
°C
41°F
°C
50°F
°C
59°F
°C
Result
38
30
24
19.5
16
Status
Windy
No windy
SVC Action
Go to the 4
Check the R Fan motor
Check the damper
(Go to the 6)
5
Check the air temperature.
Cold or not ?
Status
Cold
Not cold
SVC Action
Explain to customer
Check the Compressor
And sealed system
Содержание LFX31915 Series
Страница 20: ... 20 5 CIRCUIT DIAGRAM ...
Страница 22: ... 22 7 PCB PICTURE 7 1 Main PCB P No MFG EBR75234702 2011 01 Picture CON2 CON3 CON1 CON5 CON6 CON7 ...
Страница 23: ... 23 7 2 Display PCB Sub PCB P No Display PCB EBR 729554 2011 03 Sub PCB EBR60070709 2011 01 Picture ...
Страница 86: ...P No MFL62188080 JUL 2013 Printed in Korea ...