- 31 -
8-8 Refrigerator Fan Error (Er rF)
No
1
2
Checking flow
Reset the unit and
Input Test 1 Mode.
(Push the button 1 time)
Open the freezer door and Check the air
flow.
4
Check the Fan motor voltage.
Result & SVC Action
Below 12 V
0 or 5 V
(1) ~ (2)
(1) ~ (3)
Change the PCB
Change the motor
Point
Result
SVC Action
<CON6>
(3) (2) (1)
Status
No windy
Windy
SVC Action
Go to 3
Go to 4