- 29 -
8-6 Defrost Heater Error (F dH)
Fuse-M
Def’
Heater
Def’
Sensor
0
34~42
22
OFF
Go to the 3
Change Fuse-M
Go to the 3
Change Fuse-M
Go to the 3
Replace product
Part
Result
SVC Action
No
1
2
Checking flow
Check the Door gasket.
Check the Defrost control part.
3
Input Test 3 Mode.
(Push the button 3 times)
4
Check the Blue to Orange.
Result & SVC Action
Fuse
M
Def’
Heater
Defrost
Sensor
5
Release the test mode.
push the button 1 times. (normal)
<CON3>
<CON3>
Result
112 ~ 116 V
0 V
SVC Action
Go to the 5
Replace Main PCB
6
Check the Blue to Orange.
Result
0 V
112 ~ 116 V
SVC Action
Explain to customer
Replace Main PCB
Содержание LFX31915 Series
Страница 20: ... 20 5 CIRCUIT DIAGRAM ...
Страница 22: ... 22 7 PCB PICTURE 7 1 Main PCB P No MFG EBR75234702 2011 01 Picture CON2 CON3 CON1 CON5 CON6 CON7 ...
Страница 23: ... 23 7 2 Display PCB Sub PCB P No Display PCB EBR 729554 2011 03 Sub PCB EBR60070709 2011 01 Picture ...
Страница 86: ...P No MFL62188080 JUL 2013 Printed in Korea ...