54 Multi Air Conditioner
Installation
Connect the cable to the indoor unit
1. Connect the wires to the terminals on the control
board individually according to the outdoor unit con-
nection.
• Ensure that the color of the wires of outdoor unit and the
terminal No. are the same as those of indoor unit respec-
tively.
(Refer to Wiring diagram on page16.)
2. Attach the Grille onto the cabinet.
• Grasp lower the left and right side of the Grille and
engage four tabs on the top inside edge of the chassis.
• Press the Grille toward the chassis until it will be back into
place.
Air
Conditioner
Circuit Breaker
Use a circuit
breaker or time
delay fuse.
Connecting cable
Main power source
If a power plug is not to be used, provide a circuit breaker between power source and the unit as shown below.
WARNING
• Be sure to refer to the wiring diagram label inside the
cover control and carry out the correct field wiring.
Wrong wiring can cause the unit to misoperate to result
in a fire hazard.
• Check local electrical codes and any specified wiring
instructions or limitations.
CAUTION
Содержание L2-C242GL0
Страница 13: ...Service Manual 13 Dimensions 900 1 225 370 L3 C482LL0 ...
Страница 18: ...18 Multi Air Conditioner Electronic Control Device Outdoor Unit MAIN P C B ASM L3 C362LL0 L3 C482LL0 ...
Страница 19: ...Service Manual 19 Electronic Control Device Display P C B ASM ...
Страница 20: ...20 Multi Air Conditioner Schematic Diagram Schematic Diagram Indoor Unit L3 C362LL0 L3 C482LL0 ...
Страница 21: ...Service Manual 21 Schematic Diagram L2 C362LL0 ...
Страница 22: ...22 Multi Air Conditioner Schematic Diagram Outdoor Unit L3 C362LL0 ...
Страница 23: ...Service Manual 23 Schematic Diagram L3 C482LL0 ...
Страница 75: ...P No 3828A20156P January 2005 Printed in Korea ...