3-1.Preparation
ofPiping
3.Connecting
Pipesto
theIndoor
Unit
Maincause
ofgas
leakageis
defect
in
flaring
wor
k.Carr
yout
correctflar
ingw
ork
inthe
follo
wingprocedure
.
1)Cut
thepipes
andthe
cable
.
Usethe
accessory
pipingkit
orthe
pipes
purchasedlocally
.
Measurethe
distancebetw
eenthe
indoorand
theoutdoor
unit.
Cutthe
pipesa
littlelonger
than
measureddistance
.
Cutthe
cable
1.5mlonger
thanthe
pipe
length.
2)Burr
sremo
val
Completelyremo
ve
allb
urrsfrom
thecut
crosssection
ofpipe/tube
.
Putthe
endof
thecopper
tube/pipeto
downw
arddirection
asy
ouremo
ve
burrs
inorder
toa
void
tolet
burrs
dropin
the
tubing.
3)Putting
nut
on
Remove
flaren
utsattached
toindoor
andoutdoor
units,
thanput
themon
pipe/tubeha
vingcompleted
burr
removal.
(Notpossib
leto
putthem
onafter
flaring
wor
k)
4)Flaring
work
Carry
outflar
ingw
ork
usingflar
ingtool
assho
wnbelo
w .
Firmly
holdcopper
tubein
abar(or
die)as
indicateddimension
inthe
table
above
.
5)Chec
k
Comparethe
flaredw
ork
withfigure
.
Ifflare
isnoted
tobe
defectiv
e,
cutof
f
theflared
sectionand
doflar
ingw
ork
again.
Copper
tube
90
Slanted Uneven Rough
Pipe
Reamer
Point do
wn
Flare nut
Copper tube
Bar
Copper pipe
Clamp handle
Red arrow mar
k
Cone
Y ok
e
Handle
Bar
"A"
Inclined
Inside is shining without scratches
.
Smooth all round
Even length
all round
Surface
damaged
Crac
ked
Uneven
thickness
= Improper flaring =
OutsideDiameter
"A"
1/4"
0~0.5
3/8"
0.5~0.8
1/2"
0.5~0.8
5/8"
0.8~1.0
3/4"
1.0~1.3
12
Содержание JBNQ18GB2A1
Страница 8: ...Cooling Mode 8 ...
Страница 9: ...Auto Operation Mode 9 ...
Страница 10: ...Dehumidification Mode 10 ...
Страница 12: ...Temperature Setting Room Temperature Checking 12 ...
Страница 13: ...Timer 13 ...
Страница 17: ...Self diagnosis Function 17 ...
Страница 20: ...Wide LCD Wired Remote Controller Optional 20 ...
Страница 21: ......
Страница 22: ...27 Installer Setting Setting Address of Central Control ...
Страница 24: ...Installer Setting How to enter installer setting mode 25 ...