5-18
CONDITION
CAUSE
TEST PROCEDURE
OR CORRECTION
Uneven cooking
Dirt on the sensor filter
Remove the dirt from the
filter.
Error mode ÒError-01Ó
displays.
Shield wire connector is
loosen
Check the connector.
Incorrect resistance of
shield wire connector.
Refer to page 5-12.
Replace sensor assy
ÒGuide sensorÓ stuck.
Check and adjust the
ÒGuide sensorÓ
Refer to schematic diagram
and adjust it.
Unsuitable utensil was
used.
Use suitable utensil.
Refer to the ownerÕs
manual.
Incorrect connection of
shield wire.
Refer to page 5-12.
Replace sensor assy
Incorrect resistance of
shield wire connector.
(TROUBLE 6) Uneven cooking and error during sensor cook and temperature process.