CIRCUIT DESCRIPTION
GENERAL DETAILS
¥ The low voltage transformer supplies the necessary
voltage to the micom controller when power cord is
plugged in.
¥ When the door is closed, the primary switch is ON, the
secondary switch is ON, and the monitor switch opens
(contact COM and NO).
WHEN SELECTING COOKING POWER
LEVEL AND TIME
¥ The micom controller memorizes the function you set.
¥ The time you set appears in the display window.
¥ Each indicator light turns on to indicate that the stage
has been set.
WHEN TOUCHING THE START PAD
¥ The coil of the relay is energized by the micom
controller.
¥ Power input is supplied to the high voltage transformer
through the fuse to the primary switch and relay 2.
¥ Turntable rotates.
¥ The fan motor rotates and cools the magnetron by
blowing the air (coming from the intake on the base-
plate).
¥ The air is also directed into the oven to exhaust the
vapor in the oven through the upper plate.
¥ Cooking time starts counting down.
¥ 3.3 volts AC is generated from the filament winding of
the high voltage transformer. This 3.3 volts is applied to
the magnetron to heat the magnetron filament through
two noise-preventing choke coils.
¥ A high voltage of approximately 2100 volts AC is
generated in the secondary of the high voltage
transformer which is increased by the action of the high
voltage diode and charging of the high voltage
capacitor.
¥ The negative 4,000 Volts DC is applied to the filament
of the magnetron.
WHEN THE OVEN IS SET AT ANY LEVEL
EXCEPT MAXIMUM.
¥ The micom controller controls the ON-OFF time of
relay 2 by the applied signal to vary the average output
power of microwave oven as POWER LEVEL.
(refer to page 1-1)
¥ One complete cycle of relay 2 is 22 seconds.
WHEN THE DOOR IS OPENED DURING
COOKING
¥ Both the primary switch and relay 2 cut off the primary
winding voltage of the high voltage transformer.
¥ ON-OFF of relay 2 is coupled electrically with opening
and closing of the secondary switch.
¥ When the door is opened, the secondary switch is
opened and when the door is closed, the secondary
switch is closed.
¥ The cooking time stops counting down.
¥ Relay stops functioning.
¥ As the door is opened, if the contact of primary switch
and relay2 and/or secondary switch fail to open, the
fuse opens due to the large current surge caused by
the monitor switch activation, which in turn stops
magnetron oscillation.
4-4
FUSE
H.V.
TRANS-
FORMER
RELAY 2
MICOM CONTROLLER
SECONDARY
SWITCH
MONITOR
SWITCH
N
PRIMARY
SWITCH
L
FUSE
H.V.
TRANS-
FORMER
RELAY 2
MICOM CONTROLLER
SECONDARY
SWITCH
MONITOR
SWITCH
N
PRIMARY
SWITCH
L
Содержание GoldStar MA-1302S
Страница 30: ...6 2 13581A 13720D 13213A 13552A 15006A 13536A 14890A 14026A 14970A WTT040 13650A DOOR PARTS ...
Страница 31: ...6 3 24781S 23806C 23572A 268712 268711 249401 250201 CONTROL PANEL PARTS ...
Страница 33: ...6 5 WSZ085 43501A 466001 466003 466001 43500A LARCH BOARD PARTS ...
Страница 34: ...6 6 54974T 55900A 50CZZH 54810C WSZ002 WSZ002 WTT037 56549F 54974S 56201A SUCTION GUIDE PARTS ...
Страница 36: ...6 8 63302L 56170D 63302R WSZ002 WTT021 647781 647781 WTT030 63303R 63303L 948502 BASE PLATE PARTS ...
Страница 37: ...8 1 SCHEMATIC DIAGRAM OF P C B ...
Страница 38: ...8 2 PRINTED CIRCUIT BOARD ...
Страница 39: ...P NO 3828W5S0845 June 1999 Printed in Korea ...