5-17
CONDITION
CHECK
RESULT
CAUSE
REMEDY
No microwave
oscillation.
No continuity.
Continuity.
Abnormal
Defective high
voltage
transformer.
Replace high
voltage
transformer.
Normal
Defective PCB
assembly.
Replace PCB
assembly.
Disconnect the
wire leads from
relay 2 and
check continuity
of relay 2.
(Operate the unit)
Check high vol-
tage transformer
Output is full power
when you set lower
power level.
Abnormal.
Defective PCB
assembly.
Replace PCB
assembly.
Disconnect the
wire leads from
relay 2 and check
continuity relay 2.
(Operate the unit)
Abnormal
Defective high
voltage capacitor.
Replace high
voltage capacitor.
Normal
Check high vol-
tage capacitor.
Abnormal
Defective high
voltage diode.
Replace high
voltage diode.
Normal
Check high vol-
tage diode.
Abnormal
Defective
magnetron.
Replace
magnetron.
Check
magnetron.
(TROUBLE 5) No microwave oscillation even though oven lamp and fan motor run.
(Display operates properly)
NOTE : ¥ Make sure the wire leads correct position.
¥ When Removing the wire leads from the parts, be sure to grasp the connector, not the wires.
¥ When removing the magnetron, be sure to install the magnetron gasket in the correct position
and in good condition.
Содержание GoldStar MA-1302S
Страница 30: ...6 2 13581A 13720D 13213A 13552A 15006A 13536A 14890A 14026A 14970A WTT040 13650A DOOR PARTS ...
Страница 31: ...6 3 24781S 23806C 23572A 268712 268711 249401 250201 CONTROL PANEL PARTS ...
Страница 33: ...6 5 WSZ085 43501A 466001 466003 466001 43500A LARCH BOARD PARTS ...
Страница 34: ...6 6 54974T 55900A 50CZZH 54810C WSZ002 WSZ002 WTT037 56549F 54974S 56201A SUCTION GUIDE PARTS ...
Страница 36: ...6 8 63302L 56170D 63302R WSZ002 WTT021 647781 647781 WTT030 63303R 63303L 948502 BASE PLATE PARTS ...
Страница 37: ...8 1 SCHEMATIC DIAGRAM OF P C B ...
Страница 38: ...8 2 PRINTED CIRCUIT BOARD ...
Страница 39: ...P NO 3828W5S0845 June 1999 Printed in Korea ...