5-10
COMPONENTS
TEST PROCEDURE
RESULTS
HIGH VOLTAGE
CAPACITOR
HIGH VOLTAGE
DIODE
NOTE :
Some inexpensive meters
may indicate infinite
resistance in both direction.
Measure the resistance.
(Ohm-meter scale: Rx1000)
¥ Terminal to terminal.
Measure the resistance.
(Ohm-meter scale: Rx1000)
¥ Terminal to case.
Measure the continuity (Forward).
(Ohm-meter scale: Rx10000)
Measure the continuity (Reverse).
(Ohm-meter scale: Rx10000)
Normal: Momentarily indicates
several ohms, and
then gradually returns
to infinite.
Normal: Infinite.
Normal: Continuity.
Abnormal: Infinite.
Normal: Infinite.
Abnormal: Continuity.
NOTE: When testing the magnetron, be sure to install the magnetron gasket
in the correct position and be sure that the gasket is in good condition.
Antenna
Gasket
Chassis
Filament
Содержание GoldStar MA-1302S