12. RF Calibration
Copyright © 2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
12.1 Overview
RF Calibration is the PC side Calibration tool that perform Tx, Rx and Battery Calibration
with Agilent 8960(GSM call setting instrument) and Tektronix PS2521G(Programmable Power supply).
Auto-cal generates calibration data by communicating with phone and measuring equipment then write
it into calibration data block of flash memory in GSM phone.
4. 0
0
0
V0. 00
00
A
12.2 Procedure
1. Copy the file to C:\Cm_Gsm_Multi
2. Copy the files of((Windows XXX)MFCD DLL, vsflex7l_ocx_regist to C:\Cm_Gsm_Multi\dll,ocx
3. Select MFCD DLL of your computer OS
4. Click on “vsflex7l_ocx_regist”
5. Click on “Multi_HK reg”
6. Connect as Fig 12-2 (RS232 serial cable is connected between COM port of PC, in general.)
7. Run HK_30exe to start calibration.
8. Click “Logic Operation” of “SETTING” menu bar
9. Set PORT (using RS232 cable) that
PC can communicate with the phone
10. Select “LOGIC MODE” that
you want Logic mode:
1-> Calibration only
2-> Auto test only
3-> Cal & Auto
12. RF Calibration