15
DIAGNOSTIC TEST
47
Data Name
Entering
the test mode
1. Entering programming mode
2. WHITES AND COLORS
3. START
Insert service card (card type), Turn on/off toggle switch (Coin type).
Press the WHITES AND COLORS button. Then appears in the
display.
Enter the diagnostic test mode.
Button
Display
Description
Entering the test mode
1. This TEST should be used for Factory test /Service test. Do not use this DIAGNOSTIC TEST other than specified.
2. Activating the heater manually with the door open may trip the thermostat attached to the heater, therefore do
not activate it manually. (Do not press the door switch to operate the heater while the door is open).
This program has been added for testing the dryer and detecting errors.
During LqC1 test, if no buttons are pressed for 4 minutes, machine will be turned off automatically.
Do not use .
Note
Number of times the START
button is pressed
Display
Checking point
None
1 time
2 times
3 times
4 times
5 times
6 times
During check, if the door is open.
During check, if the door is closed
Check the version and code of machine.
ELECTRIC TYPE : US:OE
GAS TYPE : US:Og
Motor runs.
ELECTRIC TYPE: Heater runs.
Motor + Heater 1 (2700W)
GAS TYPE: GAS valve runs.
Motor + Valve
ELECTRIC TYPE: Heater runs.
Motor + Heater 1 +Heater 2 (5400W)
GAS TYPE: GAS valve runs.
Motor+Valve
LED & KEY CHECK
Press WHITES AND COLORS button.
Press PERMANENT PRESS button.
Press DELICATES button.
Test ends.
Door switch
(Motor & Heater Off, Buzzer beeps seven
times)
Test goes back at step 2.
(Motor on & Heater Off)
LqC 1
Version and code of machine (All LED on)
Display US:OE or US:Og and gU:XX
alternately. XX is the version number.
Measured moisture value (70~239)
Current temperature (5~70)
(Displays the temperature inside the drum in
° Celsius.)
Current temperature (5~70)
(Displays the temperature inside the drum in
° Celsius.)
Version and code of machine
LqC 1
dE
(The door is open. Please close the door
completely)
Measured moisture value (70~239)
Diagnostic test: (display)
11
Pressing the START button cycles to the next test function.
Содержание / GD1329QES
Страница 2: ...MARCH 2010 PRINTED IN KOREA P No MFL62119919 ...
Страница 46: ...13 CONTROL LAY OUT 45 PWB ASSEMBLY DISPLAY LAY OUT PWB ASSEMBLY LAY OUT ...
Страница 69: ...EXPLODED VIEW 19 19 1 1 Control Panel Plate Assembly Coin Type A210 A120 A110 68 ...