58
CHANGE GAS SETTING (NATURAL GAS, PROPANE GAS)
1
7
STEP 1 : VALVE SETTING
Closed
Opened
Full open
Adjustment screw
STEP 2 : ORIFICE CHANGE
Orifice
Gas type
Natural Gas
Propane Gas
Marking
NCU
PCU
Shape
Orifice P/No
4948EL4001B
4948EL4002B
Close
Adjustment screw
①
Remove 2 screws.
②
Disassemble the pipe assembly.
③
Replace natural gas orifice with propane gas orifice.
※
Kit contents
: Orifice (Dia. = 1.613mm, for Propane Gas)
Replace Label
Instruction Sheet
WARNING
• Conversion must be made by a qualified technician.
• Changing orifices and gas valve adjustments improperly can result in an explosion and/or fire.
!
The dryer is shipped from the factory set up and adjusted to operate on natural gas. It can be converted to operate on
propane (LPG). The conversion kit may be sold only to a licensed gasfitter, and must be performed ONLY by a licensed
gasfitter. This is not a do-it-yourself.
Note
Содержание / GD1329QES
Страница 2: ...MARCH 2010 PRINTED IN KOREA P No MFL62119919 ...
Страница 46: ...13 CONTROL LAY OUT 45 PWB ASSEMBLY DISPLAY LAY OUT PWB ASSEMBLY LAY OUT ...
Страница 69: ...EXPLODED VIEW 19 19 1 1 Control Panel Plate Assembly Coin Type A210 A120 A110 68 ...
Страница 70: ...19 1 2 Control Panel Plate Assembly Card Type A210 A120 A117 A110 69 ...