- 66 -
4 . TROUBLE SHOOTING
Checking Flow
SETTING : Enter the engineering mode, and set vibrator on at vibration of BB test menu
START
Is the voltage at pin 3
of U401 high?
YES
YES
YES
YES
NO
NO
NO
NO
NO
NO
YES
YES
YES
Check the soldering
of R315, R399
Check the soldering
of C300
Check the soldering
of C300
Replace U401
Replace U401
Replace vrbrator
Vibrator
working
Resolder R315, R399
Resolder C300
Resolder C300
Is the voltage at pin 1
of U401 high?
Is the voltage at pin 5
of U401 high?