- 38 -
Copyright © 2016 - 2017 LG Electronics Inc. All
rights reserved. Only training and service purposes.
CON7
CN1
CON201
CON2
CON1
CON3
CON5
CON6
CON203
CON10
Symptom
Check Point
1. F dS
1. Check for a loose connection
2. Check Sensor Resistance
Resistance [Ω]
CON7
19
th
pin & 20
th
pin
Short
0
Open
OFF
Other
Normal
CON7
19
th
pin & 20
th
pin
Resistance [Ω]
23ºF / -5ºC
38k
32ºF / 0ºC
30k
41ºF / 5ºC
24k
50ºF / 10ºC
19.5k
59ºF / 15ºC
16k
Defrost Controller
CON7
8-4. Defrost Sensor Error (F dS)