- 68 -
Copyright © 2016 - 2017 LG Electronics Inc. All
rights reserved. Only training and service purposes.
CON7
CN1
CON201
CON2
CON1
CON3
CON5
CON6
CON203
CON10
Symptom
Check Point
1. Freezer room lamp
doesn’t work
1. Check the freezer door switch
2. Check the door S/W resistance
3. Check the LED Lamp
Resistance [Ω]
Door S/W
Normal
0
Push S/W
Infinity
Voltage [V]
CON6
13
th
pin & 15
th
pin
11.4~12.6V
LED Lamp
LED Lamp
Voltage [V]
White & Yellow
Closed
0~2V
Open
11.4~12.6V
LED Lamp
Door S/W
CON6
8-18. Freezer lamp doesn’t work
Содержание ASBCNA0
Страница 7: ...Copyright 2016 2017 LG Electronics Inc All rights reserved Only training and service purposes 7 ...
Страница 29: ...Copyright 2016 2017 LG Electronics Inc All rights reserved Only training and service purposes 29 ...
Страница 74: ... 74 Copyright 2016 2017 LG Electronics Inc All rights reserved Only training and service purposes ...
Страница 112: ...Copyright 2016 2017 LG Electronics Inc All rights reserved Only training and service purposes 112 ...
Страница 122: ...P No MFL68488649 APR 2017 Printed in Korea ...