Service Manual 57
Troubleshooting Guide
■
Precaution in Service or Check
Even after stopping the operation of product, it takes some time to discharge the remaining electricity of the
electrolytic capacitor that was charged. Before starting a checking or repairing job, pull out the plug out of the
outlet and make sure that the lamp on the control board outdoor unit is off.
■
The Diagnosis Procedure
Check the supplied voltage to product (AC 220V/230V ± 30V).
Check the connecting cable between Indoor and Outdoor.
Check the blinking number of operation indicator
(refer to the self-diagnosis function).
Check the self-diagnosis table
• Check the condition of connectors
• The condition of P.C.B pattern.
• Check the condition of connectors.
• The condition of P.C.B pattern.
• The electronic components.
Indoor
Outdoor
1. Error indicator of air conditioner
1) Indoor : Operating LED / Outdoor : LED01M(Red) on the outdoor PCB
2) 2 more errors occur at same time
- Air conditioner Off condition : Display the error code of product off cause
- Air conditioner On condition : Display the prior Error Code
2. Cancellation of Error indicator
1) Error Code 1, 2, 3, 4, 10 : Error indicator canceled when cause of error recovered
2) Error Code 5, 8, 9 : Keep displaying Error indicator by restarting air conditioner,
although cause of error recovered
3) Error Code 6, 7 : Error indicator canceled when power reset (Power Cord Off & On)
Содержание AS-W0964DH0
Страница 64: ...Service Manual 69 Schematic Diagram Models AS W1865DH0 AS W1825DH0 Models AS W096E1G0 AS W126E1G0 ...
Страница 66: ...Service Manual 71 BOTTOM VIEW TOP VIEW Schematic Diagram Models AS W0964DH0 AS W0964GH0 ...
Страница 70: ...Service Manual 75 Schematic Diagram DISPLAY ASSEMBLY 6871A20574A 6871A20624A ...
Страница 84: ...P No 3828A20462G October 2006 Printed in Korea ...