16 Room Air Conditioner
Installation
The wall you select should be strong and solid
enough to prevent vibration
1. Mount the installation plate on the wall with
type "A" screws. If mounting the unit on a concrete
wall, use anchor bolts.
• Mount the installation plate horizontally by aligning
the centerline using a level.
2. Measure the wall and mark the centerline. It is also
important to use caution concerning the location of
the installation plate-routing of the wiring to power
outlets is through the walls typically. Drilling the
hole through the wall for piping connections must
be done safely.
Fixing Installation Plate
Installation Plate
Type "A" screw
Chassis
Hook
Installation plate
Left rear piping
Right rear piping
Ø70mm
Ø70mm
D
B
A
C
• Drill the piping hole with a ø70mm hole core drill.
Drill the piping hole at either the right or the left with
the hole slightly slanted to the outdoor side.
Drill a Hole in the Wall
5-7mm
(3/16"~5/16")
Indoor
WALL
Outdoor
A
B
C
D
S4
73
55
82
55
S5
121
62
258
62
CHASSIS
(Grade)
Distance (mm)
A
B
C
D
S4
50
105
59
105
SE
65
110
85
110
S5
95
122
235
122
CHASSIS
(Grade)
Distance (mm)
Installation plate
Left rear piping
Right rear piping
Ø70mm
Ø70mm
D
B
A
C
Type 1.
Type 1.
Type 2.
Type 2.
Содержание AS-W0964DH0
Страница 64: ...Service Manual 69 Schematic Diagram Models AS W1865DH0 AS W1825DH0 Models AS W096E1G0 AS W126E1G0 ...
Страница 66: ...Service Manual 71 BOTTOM VIEW TOP VIEW Schematic Diagram Models AS W0964DH0 AS W0964GH0 ...
Страница 70: ...Service Manual 75 Schematic Diagram DISPLAY ASSEMBLY 6871A20574A 6871A20624A ...