- 75 -
Copyright ©2009 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
5. Trouble Shooting
6.13 Check code Trouble shooting CH23, CH28
Check the wire
connection.(U,V,W)
Is it normal ?
Is it normal ?
Yes
Yes
No
Correct
connection
No
Change
Compressor
Check the input power
Is it normal ?
Yes
No
Change
Compressor
Check Flow Chart
❊
Dc link voltage table
❊
Check TRANS1
❊
Check DC link voltage
Type
Non operating
Operating
1 Phase AUUW243D[LUU245HV]
PFC
DC300V
±
10%
DC380V
±
10%
AUUW423D[LUU425HV]
PFC
DC300V
±
10%
DC380V
±
10%
Model
DC Link Voltage
V
CN_TRANS 1
23
28
DC Link
Low voltage.
DC Link
High voltage
• 1ph : DC link volt. is
140Vdc .
• 3ph : DC link volt. is
250Vdc .
• 1ph : DC link volt. is
140Vdc .
• 3ph : DC link volt. is
250Vdc .
• Check the power source.
• Check the components.
• Check the power source.
• Check the components.
Display
code
Title
Cause of error
Check point & Normal condition
→
→
→
→