Part 2 Functions & Controls
Press button to save or release.
6
Press button to exit or the system
will automatically exit after 25 seconds
without any input.
7
❊
Weak and Power setting is not available for some products.
❊
Because the ESP value is already appropriately set when manufactured from the factory, it is recommended that you do
not change the ESP value.
4.2 High Ceiling operation
Function to Control the Air Volume by Ceiling Height Control of the air intensity has been made possible by employing a
height-control algorithm for the interior fan.
According to the height of the installation, it provides variability of indoor fan motor rpm. If the height of installation is low
then you can adjust low rpm of indoor fan motor. On the other hand if the height of the installation is high you can adjust
high rpm of indoor fan motor. Selection of speed can be done by slide switch at the back of the LCD wired remote.