5. Trouble Shooting
- 154 -
Copyright © 2016 - 2020 LG Electronics Inc.
All rights reserved. Only training and service purposes.
NG
NG
OK
Purpose
Installation environment interfering
the communication
Items for checking
Check installation error points
ڸ
The communication lines of the
indoor /outdoor devices are in-
stalled by wire-to-wire ethod.
: In case of additional connection,
connect the wires with soldering
as shown below.
ڹ
Wire tongue-termination fault.
ں
The cut section of the wire passes
the insulation tape and causes a
short with another wire.
ڻ
Communication noise by oxidized
wire arrangement : Soldering is
required.
Wire-to-Wire
Neutral
Neutral
Installation environment interfering with the communication of
indoor/outdoor devices
6.7 Troubleshooting Outdoor Error
CH 05/53 (Indoor/Outdoor Device Communication Error)
→
Detection by indoor devices