- 76 -
Copyright © 2016 - 2020 LG Electronics Inc.
All rights reserved. Only training and service purposes.
5. Trouble Shooting
1.3 Error Indicator (Outdoor)
Outdoor Error
Ex) Error 21 (DC Peack)
1 Time
1 Time
1 Time
2 Times
2 Times
2 Times
1 Second
2 Seconds
1 Second
1 Second
LED01G
(RED)
LED02G
(GREEN)
2 Seconds
◑
: A light on the display panel is blink.
Error
Code
Contents
LED01G/M
(Red)
LED02G/M
(Green)
case of Error
Outdoor
Status
21
DC Link Peak (IPM Fault)
2times
◑
1times
◑
Over Rated Current
Off
22
CT 2 (Max CT)
2times
◑
2times
◑
Input Over Current
Off
23
DC Link Low Volt.
2times
◑
3times
◑
DC Link Volt is below 140Vdc
Off
DC Link High Volt.
DC Link Volt is above 420Vdc
25
Low Voltage/Over Voltage
2times
◑
5times
◑
Abnormal AC Volt Input
Off
26
DC Compressor Position Error
2times
◑
6times
◑
Compressor Starting Fall Error
Off
27
PSC/PFC Fault Error
2times
◑
7times
◑
Over Inverter PCB input current
Off
29
COMP Over Current
2times
◑
9times
◑
Over Inverter Compressor Current
Off
32
D-Pipe High
3times
◑
2times
◑
D-Pipe Temp. High
Off
35
Low Pressure Error
3times
◑
5times
◑
Excessive decrease of Low Pressure
Off
39
Communication Error
3times
◑
9times
◑
Communication Error Between PFC
Micom and INV Micom
Off
40
CT Sensor (Open/Short)
4times
◑
○
CT Circuit Malfunction
Off
41
INV. D-Pipe Th Error
4times
◑
1times
◑
Open/Short
Off
43
High Pressure Sensor Error
4times
◑
3times
◑
Open/Short
Off
44
Outdoor Air Th Error
4times
◑
4times
◑
Open/Short
Off
45
Cond. Mid-Pipe Th Error
4times
◑
5times
◑
Open/Short
Off
46
Suction Pipe Th Error
4times
◑
6times
◑
Open/Short
Off
48
Cond. Out-Pipe Th Error
4times
◑
8times
◑
Open/Short
Off
51
Capacity Over
5times
◑
1times
◑
Over combination
Off
53
Signal Error (Indoor <-> Outdoor)
5times
◑
3times
◑
Communication Poorly
Off
54
3-Phase Wrong wiring
5times
◑
4times
◑
3-Phase Wrong Wring of Outdoor Unit
(Reverse Phase/Omission of Phase)
Off
60
EEPROM Check Sum Error
6times
◑
○
Check Sum Mismatching
Off
61
Cond. Pipe Th High
6times
◑
1times
◑
Cond. Temp. High
Off
62
Heaksink Th High
6times
◑
2times
◑
Heatsink Temp. High
Off
65
Heaksink Th Error
6times
◑
5times
◑
Open/Short
Off
67
Outdoor BLDC Fan Lock
6times
◑
7times
◑
Outdoor Fan is not operation
Off
73
PFC Fault Error(S/W)
7times
◑
3times
◑
Over Current of Outdoor Unit PFC
Off