background image

İTHALATÇI FİRMA

LG ELECTRONICS TİCARET A.Ş.

Kaptanpaşa Mahallesi Piyalepaşa Bulvarı

No:73 Ortadoğu Plaza Kat:7 34384

Okmeydanı / Şişli / İstanbul

Tel: (0 212) 314 52 52

Faks: (0 212) 222 61 44

ÜRETİCİ FİRMA

LG Electronics Inc.

Changwon 2nd factory 84, Wanam-ro, 

Seongsan-gu, Changwon-si 

Gyeongsangnam-do, KOREA

www.lg.com

Содержание ABNH09GL1A2

Страница 1: ... must be performed in accordance with the national wiring standards by authorized personnel only Please retain this installation manual for future reference after reading it thoroughly Ceiling Concealed Duct Low static Original instruction INSTALLATION MANUAL AIR CONDITIONER P NO MFL67855525 ENGLISH TÜRKÇE ...

Страница 2: ...ditioner Installation Manual CONTENTS Safety Precautions 3 Installation Parts 6 Installation 7 Remote Controller Installation 15 Optional Operation 19 How to Set E S P 26 Self diagnosis Function 28 Dip Switch Setting 28 ...

Страница 3: ...cord a plug or a loose socket which is damaged Otherwise it may cause a fire or electrical shock For installation of the product always contact the service cen ter or a professional installation agency Otherwise it may cause a fire electrical shock explosion or in jury Securely attach the electrical part cover to the indoor unit and the service panel to the outdoor unit If the electrical part cove...

Страница 4: ...njury Do not share the outlet with other appliances It will cause an electric shock or a fire due to heat genera tion Do not use the damaged power cord Otherwise it may cause a fire or electrical shock Do not modify or extend the power cord randomly Otherwise it may cause a fire or electrical shock Take care so that the power cord may not be pulled dur ing operation Otherwise it may cause a fire o...

Страница 5: ...t Keep level parallel in installing the product Otherwise it may cause vibration or water leak age Avoid excessive cooling and perform venti lation sometimes Otherwise it may do harm to your health Use a soft cloth to clean Do not use wax thinner or a strong detergent The appearance of the air conditioner may de teriorate change color or develop surface flaws Do not use an appliance for special pu...

Страница 6: ... vents Wired Remote Controller Name Quantity Shape for gas pipe for liquid pipe Clamp metal 2 EA Insulation for fitting 1 set Drain hose 1 EA Clamp Tie Wrap 8 EA Washer for hanging bracket 4 EA Other Screws for fixing panels are attached to decoration panel Owner s manual Installation manual ...

Страница 7: ...d by an electrical noise The place where air circulation in the room will be good There should not be any heat source or steam near the unit Confirm the positional relationship between the unit and suspension bolts Installation the ceiling opening to clean the fil ter or service under the product Inspection hole 600 x 600 Control box H 20 or more Suitable dimension H is necessary to get a slope to...

Страница 8: ...e leveled and that can support the weight of the unit A place where the unit can withstand its vibra tion A place where service can be easily per formed C E G D F I A J B H Drainage hole M10 Nut M10 washer X 4 X 4 M10 Nut M10 washer X 4 X 8 Ceiling dimension and hanging bolt location POSITION OF SUSPENSION BOLT Unit mm Dimension Capacity kBtu h A B C D E F G H I J 9 733 772 628 700 36 190 20 660 1...

Страница 9: ... connection Ensure that the color of the wires of outdoor unit and the terminal No are the same as those of in door unit respectively CAUTION Tighten the nut and bolt to prevent unit falling Terminal Block Indoor Terminal Block Indoor 1 L 2 N 3 Outdoor unit Indoor unit Terminal Block outdoor 1 L 2 N 3 1 Set anchor Old building New building 2 Plate washer 3 Spring washer 4 Nut 5 Suspension bolts In...

Страница 10: ...hey are all tightly fastened If they are loose it could give rise to burn out of the wires 4 Specification of power source 5 Confirm that electrical capacity is sufficient 6 Be sure that the starting voltage is maintained at more than 90 percent of the rated voltage marked on the name plate 7 Confirm that the cable thickness is as specified in the power sources specifi cation Particularly note the...

Страница 11: ...suction from back side Low static duct type in case of suction from bottom side In case of suction from bottom size bend the Panel rear and screw with cabinet case Part name and functions Air outlet Air Filter Panel Rear Air outlet Air Filter Panel Rear Panel Rear Cabinet case ...

Страница 12: ...unit safely grounded THERMAL INSULATION TEST AND CHECK Make sure that there is no clearance here Overlap with thermal insulator for piping Thermal insulator for refrigerant pipe Local supply Thermal insulator for piping Local supply Hose clip for thermal insulator Local supply Refrigerant pipe and thermal insulator Local supply Thermal insulator for refrigerant pipe Local supply Hose clip for ther...

Страница 13: ...eck the drain pump for normal operat ing and noise when electrical wiring is complete When the test is complete connect the flexible drain hose to the drain port on the indoor unit Part name and functions Upward routing not allowed Pipe clamp Maintenance drain port Indoor unit CAUTION Ceiling Drain Pump use Drainage hole Front of view 1 Install declination of the indoor unit is very important for ...

Страница 14: ...d or screwed hose may cause a leakage of water 1 50 1 100 slope Hanger distance Hanger Bracket Max 700mm Flexible drain hose Insulation Metal clamp Max 300mm 1 15m HAND OVER Teach the customer the operation and maintenance procedures using the operation manual air filter cleaning temperature control etc ...

Страница 15: ...good air circulation at an average temperature Do not install the remote controller where it can be affected by Drafts or dead spots behind doors and in corners Hot or cold air from ducts Radiant heat from sun or appliances Concealed pipes and chimneys Uncontrolled areas such as an outside wall behind the remote controller This remote controller is equipped with a seven segment LED display For pro...

Страница 16: ...ide groove with long nose Reclamation to the surface of the wall Upper part guide groove Right part guide groove 3 Please fix remote controller upper part into the setup board attached to the surface of the wall as the picture below and then connect with setup board by pressing lower part Please connect not to make a gap at the remote con troller and setup board s upper and lower right and left pa...

Страница 17: ...de When installing the wired remote controller do not bury it in the wall It can cause damage in the temperature sensor Do not install the cable to be 50m or above It can cause communication error When installing the extension cable check the connecting direction of the connector of the remote con troller side and the product side for correct installation If you install the extension cable in the ...

Страница 18: ... don t receive the wireless signals 7 Air flow button 8 Subfunction button 9 Function setting button 10 Ventilation button 11 Reservation 12 Up down left right button To check the indoor temperature press button 13 Room temperature button Displays only the room temperature of the remote controller perception There is no control of room temperature In case of fresh air intake unit displays only the...

Страница 19: ... pressing button long for 3 seconds it enters into remote controller setter setup mode If pressing once shortly it enters into user setup mode Please press more than 3 seconds for sure Please cancel the right and left of wind direction for RAC product 1 Setup figure 01 blinks at the lower part of indication window 2 Installer Setting Test Run Mode After installing the product you must run a Test R...

Страница 20: ... pressing button 5 Press button to save 6 Pressing button will exit settings mode After setup it automatically gets out of setup mode if there is no button input for 25 seconds When exiting without pressing set button the manipulated value is not reflected 7 If entering into address setup mode by using button it indicates as picture below 2 If pressing button long for 3 seconds it enters into remo...

Страница 21: ...lly gets out of setup mode if there is no button input for 25 seconds When exiting without pressing set button the manipulated value is not reflected j The function of 2TH has different operation characteristics according to the product Thermistor Table This is the function to select the temperature sensor to judge the room temperature Temperature sensor selection Function 01 Remote controller Ope...

Страница 22: ...s picture below 2 Pressing button will exit settings mode After setup it automatically gets out of setup mode if there is no button input for 25 seconds When exiting without pressing set button the manipulated value is not reflected 5 Remote controller Function Master Indoor unit operates based on master remote controller at group control Master is set when delivering from the warehouse Slave Setu...

Страница 23: ...up mode If pressing once shortly it enters into user setup mode Please press more than 3 seconds for sure 1 If pressing button repeatedly it moves to remote controller dry contact mode setup menu as picture below 2 Pressing button will exit settings mode After setup it automatically gets out of setup mode if there is no button input for 25 seconds When exiting without pressing set button the manip...

Страница 24: ...ds for sure 1 Press button to exit or system will automatically exit after 25 seconds without any input 5 Repeat pressing button to select Function code 12 Ex Fahrengeit Setting 2 Select Temperature unit mode by pressing button 00 Celsius 01 Fahrenheit 3 Press button to save or release 4 This function is used for switching the display between Celsius and Fahrenheit Optimized only for U S A h Whene...

Страница 25: ...s for sure 1 If pressing button repeatedly it moves to the selected option function code as picture below 2 Pressing button will exit settings mode After setup it automatically gets out of setup mode if there is no button input for 25 seconds When exiting without pressing set button the manipulated value is not reflected 5 Function Plasma purification Electric heater Dehumidifier Elevation grill V...

Страница 26: ...utton to exit After setup it automatically gets out of setup mode if there is no button input for 25 seconds When exiting without pressing set button the manipulated value is not reflected 8 Function code ESP code ESP value If you set ESP incorrectly the air conditioner may malfunction This setting must be carried out by a certificated technician This is the function that decides the strength of t...

Страница 27: ... 35 110 12 73 12 09 11 22 10 14 8 83 7 30 115 13 69 13 05 12 18 11 09 9 78 8 25 120 14 67 14 02 13 16 12 07 10 76 9 23 125 15 66 15 01 14 15 13 06 11 75 10 22 130 16 67 16 02 15 16 14 07 12 76 11 23 135 16 18 15 10 13 79 12 26 140 16 14 14 83 13 30 145 15 89 14 36 ABNH12GL2A2 ABNH18GL2A2 Unit CMM Unit CMM Unit CMM ABNH24GL3A2 Setting Value Static Pressure mmAq Pa 0 0 1 10 2 20 3 30 4 40 5 50 85 10...

Страница 28: ...operation Re moval Working Off 01 Indoor Room sensor error 0 1time OFF 02 Indoor in pipe sensor error 0 2times OFF 03 Remote controller error 0 3times OFF 04 Drain pump error 0 4times OFF 05 Communication error indoor and outdoor 0 5times OFF 06 Indoor out pipe sensor error 0 6times OFF 09 EEPROM error indoor 0 9times OFF 10 BLDC motor fan lock indoor 1time 0 OFF Error Code Description LED 1 Red L...

Страница 29: ...a Mahallesi Piyalepaşa Bulvarı No 73 Ortadoğu Plaza Kat 7 34384 Okmeydanı Şişli İstanbul Tel 0 212 314 52 52 Faks 0 212 222 61 44 ÜRETİCİ FİRMA LG Electronics Inc Changwon 2nd factory 84 Wanam ro Seongsan gu Changwon si Gyeongsangnam do KOREA www lg com ...