If entering into ESP setup mode by using
button, it indicates as the picture
below.
2
Select ESP fan step by
pressing button.
(01: very low, 02: low, 03:
medium, 04: high, 05:
very high)
3
Move to ESP value setting by pressing
button.
(It is 000 when delivering
from the warehouse.)
4
Press button to setup ESP value.
(It is possible to setup ESP
value from 1 to 255, and 1 is
the smallest and 255 is the
biggest.)
5
If pressing button long for 3
seconds, it enters into remote
controller setter setup mode.
- If pressing once shortly, it enters
into user setup mode. Please press
more than 3 seconds for sure.
1
Function Code
ESP value
ESP step
Press button to save.
7
Select ESP fan step again by using
button and setup ESP value, as No. 4
and 5, that corresponds each wind flow
6
Press button to exit.
❈
After setup, it automatically gets out of
setup mode if there is no button input
for 25 seconds.
❈
When exiting without pressing set
button, the manipulated value is not
reflected.
8
Function code,
ESP code
ESP value
• If you set ESP incorrectly, the air conditioner may malfunction.
• This setting must be carried out by a certificated-technician.
This is the function that decides the strength of the wind for each wind level and because this function
is to make the installation easier.
h
When setting ESP value on the product without very weak wind or power wind function, it may not work.
How to Set E.S.P?
Installer Setting -E.S.P.
How to Set E.S.P?
26
• When setting ESP value on the product without very weak wind or power wind function, it may not work.
• Please be careful not to change the ESP value for each fan step.
• It does not work to setup ESP value for very low/power step for some products.
• ESP value is available for specific range belongs to the product.