8
Installation
Installation of Unit
Install the unit above the ceiling correctly.
• Apply a joint-canvas between the unit and duct
to absorb unnecessary vibration.
• Apply a filter Accessory at air return hole.
※ Install the unit leaning to a drainage hole side
as a figure for easy water drainage.
• A place where the unit will be leveled and that
can support the weight of the unit.
• A place where the unit can withstand its vibra-
tion.
• A place where service can be easily per-
formed.
C
E
G
D
F
I
A
J
B
H
Drainage hole
M10 Nut
M10 washer
X 4
X 4
M10 Nut
M10 washer
X 4
X 8
Ceiling dimension and hanging bolt location
POSITION OF SUSPENSION BOLT
(Unit: mm)
Dimension
Capacity
(kBtu/h)
A
B
C
D
E
F
G
H
I
J
9
733 772 628 700 36 190 20 660 155 700
12/18
933 972 628 700 36 190 20 860 155 900
24
1133 1172 628 700 36 190 20 1060 155 1100
POSITION OF CONSOLE BOLT