Service Manual
35
3. Art Cool Deluxe Type Indoor unit
• Do not have any heat or steam near the unit.
• Select a place where there are no obstacles in front of the
unit.
• Make sure that condensation drainage can be conveniently
routed away.
Do not install near a doorway.
• Ensure that the space around the left and right of the unit is
more than 20cm. The unit should be installed as high on the
wall as possible, allowing a minimum of 30cm from ceiling.
• Use a stud finder to locate studs to prevent unnecessary
damage to the wall.
4. Duct Type Indoor Unit
Install the air conditioner in the location that satisfies the
following conditions.
• The place shall easily bear a load exceeding four times
the indoor unit’s weight.
• The place shall be able to inspect the unit as the figure.
• The place where the unit shall be leveled.
• The place shall allow easy water drainage.(Suitable
dimension “H” is necessary to get a slope to drain as fig-
ure.)
• The place shall easily connect with the outdoor unit.
• The place where the unit is not affected by an electrical
noise.
• The place where air circulation in the room will be good .
• There should not be any heat source or steam near the
unit
5. CST Type Indoor Unit
• There should not be any heat source or steam near the
unit.
• There should not be any obstacles to the air circulation.
• A place where air circulation in the room will be good.
• A place where drainage can be easily obtained.
• A place where noise prevention is taken into considera-
tion.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the wall,
ceiling, or other obstacles.
• The indoor unit must have the maintenance space
around.
Unit:cm
Ceiling
Ceiling Board
Ceiling Board
30 or more
Abo
ve
250
330 or less
100
or more
50 or
more
50 or
more
30 or less
Floor
Installation
More than 20cm
More than 30cm
More than 2.3m
More than 30cm
Install the indoor unit on the wall where the height
from the floors more than 2.3 meters.
CAUTION
H
600
600
Top view
(unit: mm)
Front view
Front
Inspection hole
(600X600)
Control box
1000
Содержание A2UW146FA0
Страница 143: ...Service Manual 143 Schematic Diagram 2 Art Cool Type ...
Страница 144: ...144 Multi type Air Conditioner Schematic Diagram 3 Art Cool Deluxe Type A C MOTOR ...
Страница 145: ...Service Manual 145 Schematic Diagram 3 Art Cool Deluxe Type BLDC MOTOR ...
Страница 147: ...Service Manual 147 Schematic Diagram SLIM DUCT B1 B2 ...
Страница 157: ...Service Manual 157 Schematic Diagram 15 SLIM DUCT B1 B2 ...
Страница 161: ...Service Manual 161 Schematic Diagram 2 Art Cool Type TOP VIEW BOTTOM VIEW ...
Страница 163: ...Service Manual 163 Schematic Diagram TOP VIEW BOTTOM VIEW 3 Art Cool Deluxe Type BLDC MOTOR ...
Страница 164: ...164 Multi type Air Conditioner Schematic Diagram 4 Duct Type High static BH BG chassis Built in type BP chassis ...
Страница 165: ...Service Manual 165 Schematic Diagram Low static BT BT1 chassis ...
Страница 166: ...166 Multi type Air Conditioner Schematic Diagram TOP VIEW BOTTOM VIEW Low static B1 B2 ...
Страница 167: ...Service Manual 167 Schematic Diagram 5 Casset Type 1 way TC Chasis ...
Страница 168: ...168 Multi type Air Conditioner Schematic Diagram 1 way TC1 Chasis TOP VIEW BOTTOM VIEW ...
Страница 169: ...Service Manual 169 Schematic Diagram 4 way TE TF TD chassis 4 way TE1 TH chassis TOP VIEW BOTOM VIEW 58 B ...
Страница 171: ...Service Manual 171 Schematic Diagram VB chassis ...
Страница 172: ...172 Multi type Air Conditioner Schematic Diagram VB chassis TOP VIEW BOTOM VIEW ...
Страница 175: ...Service Manual 175 Schematic Diagram 3 Outdoor Unit 1 Component side ...
Страница 176: ...176 Multi type Air Conditioner Schematic Diagram 2 Solder side ...
Страница 177: ...Service Manual 177 Schematic Diagram 3 Central control PCB 2 Bottom View 1 Top View ...
Страница 178: ...178 Multi type Air Conditioner 4 SUB P W B ASSEMBLY 1 Art Cool Type TOP VIEW BOTTOM VIEW Schematic Diagram ...
Страница 268: ...P No 3828A20097W April 2006 Printed in Korea ...