Multi type Air Conditioner
■
Error Indicator
• The function is to self-diagnoisis airconditioner and express the troubles identifically if there is any trouble.
• Error mark is ON/OFF for the operation LED of evaporator body in the same manner as the following table.
• If more than two troubles occur simultaneously, primarily the highest trouble fo error code is expressed.
• After error occurrence, if error is released, error LED is also released simultaneously.
• To operate again on the occurrence of error code, be sure to turn off the power and then turn on.
• Having or not of error code is different from Model.
Troubleshooting Guide
Self-diagnosis Function
Indoor Error
Error code
Description
INV TPS
LED 1
(Red)
LED 2
(Green)
Indoor
Status
00
No Error
ON
01
Indoor Room themistor error
1time
OFF
02
Indoor in-piping sensor error
2times
OFF
03
Remote controller error
3times
OFF
04
Drain Pump error
4times
OFF
05
Communcation error between in and out
5times
OFF
06
Indoor Out-Piping sensor error
6times
OFF
07
Differnt mode operation
7times
OFF
Outdoor Error
Error Code
Description
INV TPS
LED 1
(Red)
LED 2
(Green)
Indoor
Status
21
DC Peak (IPM Fault)
2times
1time
OFF
22
CT 2(Max CT)
2times
2times
OFF
23
DC Link Low Volt.
2times
3times
OFF
24
L_P/Heater Sink
2times
4times
OFF
25
Low voltage / Over voltage
2times
5times
OFF
26
DC Comp Position Error
2times
6times
OFF
27
PSC Fault Error
2times
7times
OFF
28
DC Link High Volt
2times
8times
OFF
32
D-Pipe High (INV)
3times
2times
OFF
33
D-Pipe High (Normal)
3times
3times
OFF
40
CT Sensor (Open/Short)
4times
O
OFF
41
INV. D-PipeTh Error(Open/Short)
4times
1time
OFF
44
Outdoor air Th Error(Open/Short)
4times
4times
OFF
45
Cond. Pipe Th Error(Open/Short)
4times
5times
OFF
46
Suction Pipe Error(Open/Short)
4times
6times
OFF
47
Const D-pipe Th Error(Open/Short)
4times
7times
OFF
51
Capacity over
5times
1time
OFF
53
Signal error (Indoor
↔
Outdoor)
5times
3times
OFF
60
EEPROM Check Sum Error
6times
O
OFF
61
Cond. Pipe High
6times
1time
OFF
62
Heatsink High
6times
2times
OFF
63
Cond. Pipe Low
6times
3times
OFF
65
Heatsoml Th error (Open/Short)
6times
5times
OFF
Содержание A2UW146FA0
Страница 143: ...Service Manual 143 Schematic Diagram 2 Art Cool Type ...
Страница 144: ...144 Multi type Air Conditioner Schematic Diagram 3 Art Cool Deluxe Type A C MOTOR ...
Страница 145: ...Service Manual 145 Schematic Diagram 3 Art Cool Deluxe Type BLDC MOTOR ...
Страница 147: ...Service Manual 147 Schematic Diagram SLIM DUCT B1 B2 ...
Страница 157: ...Service Manual 157 Schematic Diagram 15 SLIM DUCT B1 B2 ...
Страница 161: ...Service Manual 161 Schematic Diagram 2 Art Cool Type TOP VIEW BOTTOM VIEW ...
Страница 163: ...Service Manual 163 Schematic Diagram TOP VIEW BOTTOM VIEW 3 Art Cool Deluxe Type BLDC MOTOR ...
Страница 164: ...164 Multi type Air Conditioner Schematic Diagram 4 Duct Type High static BH BG chassis Built in type BP chassis ...
Страница 165: ...Service Manual 165 Schematic Diagram Low static BT BT1 chassis ...
Страница 166: ...166 Multi type Air Conditioner Schematic Diagram TOP VIEW BOTTOM VIEW Low static B1 B2 ...
Страница 167: ...Service Manual 167 Schematic Diagram 5 Casset Type 1 way TC Chasis ...
Страница 168: ...168 Multi type Air Conditioner Schematic Diagram 1 way TC1 Chasis TOP VIEW BOTTOM VIEW ...
Страница 169: ...Service Manual 169 Schematic Diagram 4 way TE TF TD chassis 4 way TE1 TH chassis TOP VIEW BOTOM VIEW 58 B ...
Страница 171: ...Service Manual 171 Schematic Diagram VB chassis ...
Страница 172: ...172 Multi type Air Conditioner Schematic Diagram VB chassis TOP VIEW BOTOM VIEW ...
Страница 175: ...Service Manual 175 Schematic Diagram 3 Outdoor Unit 1 Component side ...
Страница 176: ...176 Multi type Air Conditioner Schematic Diagram 2 Solder side ...
Страница 177: ...Service Manual 177 Schematic Diagram 3 Central control PCB 2 Bottom View 1 Top View ...
Страница 178: ...178 Multi type Air Conditioner 4 SUB P W B ASSEMBLY 1 Art Cool Type TOP VIEW BOTTOM VIEW Schematic Diagram ...
Страница 268: ...P No 3828A20097W April 2006 Printed in Korea ...