iPECS eMG80/100& eMG800 & UCP & vUCP
Administration and Programming Manual
Issue 2.3
199
3.3.10 NETWORKING DATA
–
PGM 320 to 324
3.3.10.1 Network Basic Attribute
– PGM 320
PROCEDURE:
NET BASIC ATTRIBUTE
PRESS FLEX KEY (1-8)
Press the
[PGM]
button and dial 320.
Press the Flex button 1~8 for the desired setting, refer to Table 3.3.10.1-1.
Use the dial-pad to enter the required data.
Press the
[Save]
button to store the new data.
Table 3.3.10.1-1 NETWORK BASIC ATTRIBUTE (PGM 320)
BTN
ATTRIBUTE/DISPLAY
DESCRIPTION
RANGE
DEFAULT
1
NET ENABLE
(1:ON/:OFF) :OFF
Enable Networking function
0: OFF
1: ON
OFF
2
NET RETRY COUNT
(00-99) :00
Not used.
00-99
00
3
NET CNIP ENABLE
(1:ON/:OFF) :ON
The name of calling station is sent to the
called system between iPECS eMG. CNIP
is displayed at called party stations
display based on the programming.
0: OFF
1: ON
ON
4
NET CONP ENABLE
(1:ON/:OFF) :OFF
Reserved for future usage.
0: OFF
1: ON
OFF
5
NET SIGNAL METHOD
(1:FAC/:UUS) :FAC
Select the information element type for
QSIG supplementary service message.
0: UUS
1: FAC
FAC
6
NET CAS ENABLE
(1:ON/:OFF) :OFF
Not used.
0: OFF
1: ON
OFF
7
NET VPN ENABLE
(1:ON/:OFF) :OFF
Not used.
0: OFF
1: ON
OFF
8
NET CC RETAIN MODE
(1:ON/:OFF) :OFF
Not used.
0: OFF
1: ON
OFF