Installation
46
130001398_002_C0 - 09/2016 - © Leybold
Establishing Potential Equalisation
In the case of operation with a frequency converter and ground leakage
currents of over 3.5 mA, the protective ground conductor must have a
cross-section of the least 10 mm
2
. Or a further protective ground conduc-
tor having at least the same cross-section as the connection cable must
be provided.
A M10 thread is provided at the motor casing for connecting the external
potential equalisation cable.
The potential equalisation conductor must be connected as depicted in fig.
3.8.
NOTICE
Fig. 3.8 Establishing the potential equalisation at the pump casing
Washer
Lock washer
Hexagon socket screw, M 10
RUVAC WH/WHU 4400/7000
Copper strap, for example
Freely Selected Frequency Converter