Installation
45
130001398_002_C0 - 09/2016 - © Leybold
In the case of FC operation considerable electromagnetic interference occurs.
Here the limits specified in the pertinent standards and guidelines need to be
complied with under all circumstances by the installer. In order to reduce the
level of electromagnetic interference, shielded motor cables, shielded cable
feedthroughs, mains filters and EMC compliant ground connections are
required between frequency converter and pump.
In order to protect the pump, current limits in the frequency converter as a
function of the frequency must be taken into account.
Operation of the frequency converter requires the corresponding mains filter.
Note for maximum speeds that in the case of increased speeds and the
avail able maximum power, the maximum permissible pressure difference can-
not be attained.
Permissible frequencies
RUVAC
WH 2500
WH 4400
WH 7000
Minimum frequency
20 Hz
20 Hz
20 Hz
Maximum frequency
100 Hz*
80 Hz
70 Hz
* only permissible using the internal or the external frequency converter supplied
by Leybold, otherwise max. 80 Hz
Setup data for Leybold frequency converter =
recommended or mandatory settings for freely selectable frequency converters
for RUVAC WH
2500
4400/7000
4400/7000
11 kW @ 50 Hz
18.5 kW @ 50 Hz
Maximum voltage
360 V
400 V
400 V
Base frequency
120 Hz
50 Hz
50 Hz
(this is
not
the maximum frequency for the pump)
Base voltage
360 V
400 V
400 V
Nominal motor current
27 A
20 A
31 A
Number of motor poles
2
2
2
Motor outside conductor to
outside conductor resistance
0.34 Ohm
0.72 Ohm
0.55 Ohm
Nominal motor output power
14.5 kW
11 kW
18.5 kW
Warning temperature Pt 1000
80 °C
–
–
Maximum pump temperature Pt 1000
90 °C
–
–
Maximum motor temperature PTC
110 °C (only for WH(U) 2500
80 °C
80 °C
with direct mains power connection
Freely Selected Frequency Converter