Installation
38
130001398_002_C0 - 09/2016 - © Leybold
If the oil level is too low, the bearings and gearwheels are not lubricated
adequately; if it is too high oil may enter the pumping chamber and the
pump could overheat.
Clean the oil-fill port and screw the plug back in using a gasket which is in
perfect condition.
The oil-fill port must be sealed air-tight. Entry of air from the outside may
cause oil-containing gas to enter the pumping chamber via the impellers
seals.
NOTICE
min. –4 mm
max. 0 mm
Correct oil level in the oil sight glass with the pump at standstill
when using LVO 210 und PFPE
min. 0 mm
max. +4 mm
Fig. 3.6 Oil level
RUVAC
WH/WHU 2500
for vertical flow
RUVAC
WH/WHU 4400/7000
for vertical and horizontal flow