![LEYBOLD 250000 Скачать руководство пользователя страница 62](http://html1.mh-extra.com/html/leybold/250000/250000_operating-instructions-manual_1890883062.webp)
Head
63
⏐
GA10218_0101 - 5/2002
The menu for the PhoeniXL
300 Modul
version allows the following vacuum
settings which varies to the PhoeniXL
300
:
6.6.1.1 Automatic purge
Main menu
>
Settings
>
Vacuum settings
> Automatic purge
Through this menu is it possible to start automatic purge for 20 seconds
automatically.
This setting is only possible for the PhoeniXL
300 dry
and PhoeniXL
300
Modul
(refer to Chapter 5.3.1)
6.6.1.2 Vent delay
Main menu
>
Settings
>
Vacuum settings
>
Vent delay
Through this menu item it is possible to define the delay time until the inlet
port is vented when operating the STOP botton. When the STOP button is
pressed for a period of time which is shorter than the delay time specified
here, the PhoeniXL will just change to Stand-by mode.
When the STOP button is pressed for a period of time which is longer
than the delay time specified here, the PhoeniXL will vent the inlet port.
Softkey 2: Automatic purge
Refer to chapter
6.6.1.1
Softkey 3:
Vent delay
Refer to chapter
6.6.1.2
Softkey 4: Vacuum ranges
Refer to chapter
6.6.1.3
Softkey 5: Forepump set up
Refer to chapter
6.6.1.4
Softkey 6: Sniffer factor
Refer to chapter
6.6.1.5
Softkey 7:
Machine factor
Refer to chapter
6.6.1.6
Softkey 8: Leak rate internal test leak
Refer to chapter
6.6.1.7
Softkey 3:
Off
The function automatic purge is off.
Softkey 6:
ON
The function automatic purge is on. When changing from measure to
stand-by the forevacuum pump will be purged automatically for 20
seconds.