Ethernet IP
11
300802431_002_C0 - 09/2019 - © Leybold
Power-Up Diagnostic LED Sequence
Sequence
Module Status (MS)
Network Status (NS)
Time (ms)
1
Green
OFF
250
2
Red
OFF
250
3
Green
OFF
–
4
Green
Green
250
5
Green
Red
250
6
Green
OFF
–
EDS File
For easy network implantation, download the EDS file at
www.leybold.com -> Downloads -> Download Software -> PC Software for
DRYVAC and RUVAC WH pumps.
Refer to the option package labeling in the field designated “PRG” (four digit
number)” to identify the option software version
Version 1.05. (0224, 4100)
Version 1.06. (4101)
Version 1.07. (4102)
Version 1.08. (4103)
Activating the adapter card
B1-01 = 3
B1-02 = 3
3.2 Control and Monitor Parameters
F7-13
1 BootP
2 DHCP
0 User defined
If 0 is selected, set the following values:
F7-01 to F7-04
IP address
F7-05 to F7-08
Subnet mask
F7-09 to F7-12
Gateway