Cause
The anti-suck back valve is malfunctioning.
Remedy
Clean the intake port dirt-trap and anti-suck back valve
page 46.
Cause
Exhaust valve is malfunctioning.
Remedy
Repair the valve. Contact Service.
Cause
Oil is unsuitable.
Remedy
Change the oil (degas it, if necessary). Refer to
Cause
Vacuum lines are dirty.
Remedy
Clean the vacuum lines.
Cause
Pump is too small.
Remedy
Check the process data, replace the pump if necessary.
Fault
Pumping speed is too low
Cause
The inlet screen in the intake port is clogged.
Remedy
Clean the dirt-trap. Install a dust filter in an intake line to prevent clogging. Refer to
the intake port dirt-trap and anti-suck back valve
Cause
Connecting lines are too narrow or too long.
Remedy
Use adequately wide and short connecting lines.
Fault
After switching off the pump under vacuum, pressure in the system rises too fast
Cause
System has a leak.
Remedy
Check the system.
Cause
Anti-suck back valve is malfunctioning.
Remedy
Clean the intake port dirt-trap and anti-suck back valve
page 46.
Fault
Pump gets too hot
Cause
Cooling air supply is obstructed.
Remedy
Set pump up correctly.
Cause
Ambient temperature is too high.
Remedy
Set pump up correctly. Refer to
.
Cause
Process gas is too hot.
Remedy
Change the process gas.
Cause
Oil level is too low.
Remedy
Add oil to reach the correct oil level. Refer to