Installation
2
Installation
2.1
Check the product
■
Check that the package is right-side-up and then open it.
Caution
■
Check that model of the product is one that you ordered.
■
Check that there is no damage. If there is any damage,
file a damage claim with the carrier.
■
Remove inlet blank flange and outlet blank flange. If you ope
rate the pump with blank flanges, it can cause damage.
■
Check that the Air Muffler for the Air flush port is in the plastic
bag.
SC 5 D
SC 5 D OILFREE SCROLL VACUUM PUMP
Cat. No.
133 000
Motor
150 W
Cycles
Hz
50 60
Serial No.
Displacement m
3
/h
5 6.4
GmbH, 50968 Köln, Bonner Str. 498
Year
Germany
vacuum
MADE IN JAPAN
SC 15 D
SC 15 D OILFREE SCROLL VACUUM PUMP
Cat. No.
133 001
Motor
0.4 kW
Cycles
Hz
50 60
Serial No.
Displacement m
3
/h
15 18
GmbH, 50968 Köln, Bonner Str. 498
Year
Germany
vacuum
MADE IN JAPAN
SC 30 D
SC 30 D OILFREE SCROLL VACUUM PUMP
Cat. No.
133 002
Motor
0.6 kW
Cycles
Hz
50 60
Serial No.
Displacement m
3
/h
30 36
GmbH, 50968 Köln, Bonner Str. 498
Year
Germany
vacuum
MADE IN JAPAN
Fig. 9 Check the product
GA01423_0102 - 11/2004
15
Содержание SC 15 D
Страница 1: ......
Страница 7: ...Description SC 15 D SC 30 D Fig 3 Connections and controls SC 15 D 30 D GA01423_0102 11 2004 7...
Страница 12: ...Description 1 3 3 Outside dimensions SC 5 D Fig 6 Dimensional drawing for the SC 5 D 12 GA01423_0102 11 2004...
Страница 13: ...Description SC 15 D Fig 7 Dimensional drawing for the SC 15 D GA01423_0102 11 2004 13...
Страница 14: ...Description SC 30 D Fig 8 Dimensional drawing for the SC 30 D 14 GA01423_0102 11 2004...
Страница 30: ...Operation SC 15 D SC 30 D SC 5 D Fig 24 Position of Air Flush Port 30 GA01423_0102 11 2004...