Description
Motor Related Data
SC 30 D
Type
Single-phase
Induction motor 4P
Totally-Enclosed
Insulation Class B / IP 44
Thermal Protector TP 212
Automatic Reset Type
3-phase
Induction motor
5
4P
Totally-Enclosed
Insulation Class B / IP 44
Power consumption
kW
0.6
0.6
Voltage
V
100
115
200
230
200
208
230
380
415 460
Rated current
50 Hz
60 Hz
A
A
8.5
*
10
8.6
4.3
3.9
4.8
4.0
2.7
*
*
1.57
1.63
-
2.8
2.6
2.5
*
*
1.47
Speed at
50 Hz
60 Hz
min
-1
min
-1
1430
*
1660 1720
1430
1450
1690
1730
1460
*
*
1470 1470
-
1740 1740 1760
*
*
1770
Noise level
2
at 1m
with air flush ON (opened)
dB(A)
dB(A)
≤
62
≤
70
≤
60
≤
68
Direction of inlet
Horizontal (Laterally fitted)
Dimensions (L x W x H)
mm
443 x 328 x 372 (443 x 298 x 397)
372 x 328 x 372 (372 x 298 x 397)
Weight
kg
44
38
Order information
133 102
133 002
133 004
*Can not operate at 115V/50 Hz, 208V/50Hz, 230V/50Hz, 460V/50 Hz, 380V/60 Hz, or 415V/60 Hz.
Note 1 : Pumping speed remain the same when air flush is ON (opened) and OFF (closed).
Note 2 : Noise level is measured at ultimate pressure in an anechoic room.
Note 3 : Leak tightness is measured when pump is stopped and air flush is OFF (closed).
Note 4 : Air Flush is OFF (closed) when pump is delivered.
Note 5 : Three Phase Motor does not have internal thermal protection. Be sure to install thermal protection like a breaker.
1.3.2
Performance data
Pa
Pumping Speed (l/min)
10
100
1000
0
10
10
1
10
-1
10
2
10
3
10
5
1
Inlet Pressure
10
4
mbar
-2
10
10
-1
10
-3
10
0
10
1
10
3
10
2
Torr
-2
10
10
-1
10
-3
10
0
10
1
10
3
10
2
SC 30 D
60 Hz
50 Hz
SC 15 D
60 Hz
50 Hz
SC 5 D
60 Hz
50 Hz
Fig. 5 Pumping speed characteristics
GA01423_0102 - 11/2004
11
Содержание SC 15 D
Страница 1: ......
Страница 7: ...Description SC 15 D SC 30 D Fig 3 Connections and controls SC 15 D 30 D GA01423_0102 11 2004 7...
Страница 12: ...Description 1 3 3 Outside dimensions SC 5 D Fig 6 Dimensional drawing for the SC 5 D 12 GA01423_0102 11 2004...
Страница 13: ...Description SC 15 D Fig 7 Dimensional drawing for the SC 15 D GA01423_0102 11 2004 13...
Страница 14: ...Description SC 30 D Fig 8 Dimensional drawing for the SC 30 D 14 GA01423_0102 11 2004...
Страница 30: ...Operation SC 15 D SC 30 D SC 5 D Fig 24 Position of Air Flush Port 30 GA01423_0102 11 2004...