Actions
Yes
No
Step 1
Check if the printer is using a genuine and supported Lexmark
toner cartridge.
Note:
If the printer is using a third
‑
party cartridge, then refer the
users to their cartridge supplier.
Is the printer using a genuine and supported toner cartridge?
Go to step 3.
Go to step 2.
Step 2
Install a genuine and supported toner cartridge.
Does the problem remain?
Go to step 3.
The problem is
solved.
Step 3
a
Remove any packing material left on the imaging unit, including
the red separator plastic (A).
Note:
You may need a pair of pliers to remove a piece of
broken plastic inside the imaging unit.
b
Check the charge roller contact (B) on the right side of the
imaging unit for damage and proper installation.
Is the charge roller contact damaged and contaminated?
Go to step 4.
Go to step 5.
Step 4
Repair or replace the charge roller contact on the imaging unit.
Does the problem remain?
Go to step 5.
The problem is
solved.
4514-330
Diagnostics and troubleshooting
65
Содержание MS312
Страница 11: ...Part number index 335 Part name index 339 4514 330 Table of contents 11 ...
Страница 12: ...4514 330 Table of contents 12 ...
Страница 182: ...4514 330 182 ...
Страница 214: ...5 Remove the three screws B and then remove the left front mount B 4514 330 Parts removal 214 ...
Страница 230: ...5 Remove the four screws B and then remove the right front mount B 4514 330 Parts removal 230 ...
Страница 232: ...Cartridge plunger removal 1 Open the front door 2 Tilt the cartridge plunger 4514 330 Parts removal 232 ...
Страница 234: ...b Set the spring over the plunger 4514 330 Parts removal 234 ...
Страница 240: ...3 Squeeze the latches B to release the left and right links B 4514 330 Parts removal 240 ...
Страница 262: ...c Bring the cable in front of the two cable holders near the ACM shaft 4514 330 Parts removal 262 ...
Страница 263: ...d Loop the cable behind the right cable holder e Twist the cable so that it forms a loop 4514 330 Parts removal 263 ...
Страница 267: ...11 Disconnect the two springs D D 4514 330 Parts removal 267 ...
Страница 269: ...15 Rotate and then remove the 2nd pickup bushing 16 Pull out the shaft and remove the ACM 4514 330 Parts removal 269 ...
Страница 284: ...3 Swing the right cover backward to remove 4 Remove the screw D 4514 330 Parts removal 284 ...
Страница 286: ...4514 330 286 ...
Страница 291: ...4514 330 291 ...
Страница 293: ...Assembly 1 Covers 4514 330 Parts catalog 293 ...
Страница 295: ...Assembly 2 Electronics 1 1 2 3 4 5 7 8 9 6 4514 330 Parts catalog 295 ...
Страница 297: ...Assembly 3 Electronics 2 4 3 2 1 6 5 4514 330 Parts catalog 297 ...
Страница 299: ...4514 330 Parts catalog 299 ...
Страница 300: ...Assembly 4 Frame 2 5 6 9 10 11 13 14 12 8 1 4 4 3 7 4514 330 Parts catalog 300 ...
Страница 302: ...4514 330 Parts catalog 302 ...
Страница 303: ...Assembly 5 Option trays 3 4 5 6 1 2 4514 330 Parts catalog 303 ...
Страница 306: ...4514 330 Parts catalog 306 ...
Страница 308: ...4514 330 308 ...
Страница 312: ...4514 330 312 ...
Страница 314: ...4514 330 314 ...
Страница 326: ...4514 330 326 ...
Страница 338: ...4514 330 Part number index 338 ...
Страница 342: ...4514 330 Part name index 342 ...