Action
Yes
No
Step 2
a
Using the
Maintenance Defect Ruler
, measure the distance
between the repeating defects on the affected color page.
b
Replace the supply item that matches the measurement on the
affected color page.
Imaging kit or imaging unit
•
94.20 mm (3.70 in.)
•
29.80 mm (1.17 in.)
•
25.10 mm (0.99 in.)
Developer unit
•
43.90 mm (1.73 in.)
•
45.50 mm (1.79 in.)
c
Print the quality sample pages.
Do the defects still appear?
Take note of the
distance, and then
contact
or your
service
representative.
The problem is
solved.
Step 3
a
Using the
Maintenance Defect Ruler
, measure the distance
between the defects on the affected color page.
b
Replace the supply item that matches the measurement on the
affected color page.
Transfer module
•
37.70 mm (1.48 in.)
•
78.50 mm (3.09 in.)
•
55 mm (2.17 in.)
Fuser
•
95 mm (3.74 in.)
•
110 mm (4.33 in.)
•
34.60 mm (1.36 in.)
c
Print the quality sample pages.
Do the defects still appear?
Take note of the
distance, and then
contact
or your
service
representative.
The problem is
solved.
Solid color or black images
Troubleshooting
97
Содержание CS720 Series
Страница 41: ...2 Remove the waste toner bottle 3 Remove the imaging kit Maintaining the printer 41...
Страница 43: ...8 Insert the black toner cartridge 9 Insert the imaging kit Maintaining the printer 43...
Страница 45: ...2 Remove the waste toner bottle 3 Remove the imaging kit Maintaining the printer 45...
Страница 47: ...8 Insert the toner cartridges 9 Insert the new imaging kit Maintaining the printer 47...
Страница 53: ...3 Remove the pick roller 4 Unpack the new pick roller Maintaining the printer 53...
Страница 110: ...5 ISP extended cable 4 Install the ISP into its housing Upgrading and migrating 110...
Страница 111: ...5 Attach the housing to the controller board access cover Upgrading and migrating 111...
Страница 117: ...5 Open door B 6 Open door C Upgrading and migrating 117...