REMOTE WALL MOUNTED SWITCH
A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach the wall switch in a
junction box at the desired location on the wall.
See Figure 21
.
NOTE:
Extended lengths of wire may cause the fireplace not to function properly. Longer length of wire
is permitted if the wire is made out of larger gauge (diameter) wire. Always check with local
code.
Figure 21 - Wiring Diagram for Wall Switch
ELECTRICAL INSTALLATION
ELECTRICAL WIRING
Electrical connections should only be performed by a qualified, licensed electrician.
Main power must be off when connecting to main electrical power supply or performing
service. All wiring shall be in compliance with all local, city, and state codes. The
appliance, when installed, must be electrically grounded in accordance with local
codes, or in the absence of local codes, with the
National Electrical Code ANSI/ NFPA
70 (latest edition)
and
Canadian Electrical Code, CSA C22.1.
W
A
R
N
IN
G
Label all wires before disconnecting when servicing controls. Wiring errors can cause
improper and dangerous operation.
C
A
U
T
IO
N
Verify proper operation after servicing.
This insert will work without any electrical supply. Electricity is only needed
to operate the blower
.
W
A
R
N
IN
G
OFF
OFF
ON
OPTIONAL REMOTE
CONTROL
ON
OFF
OPTIONAL 15'
WALL SWITCH
PILOT ASSEMBLY
THERMOPILE
BATTERY
POWERED
IGNITOR
MILLIVOLT VALVE
TP
TH/TP
TH
THERMOCOUPLE
SPARKER
UNIT
SWITCH
ON
Do not connect
wall switch to
main
(110V)
circuit.