20
48D0586
CHECKING GAS PRESSURE
1. Check gas type. The gas supply must be the same as
stated on the applianceʼs rating decal. If the gas supply
is different from the fireplace, STOP! Do not install
the appliance. Contact your dealer immediately.
2. Install and attach 30" (762mm) flex line provided with
on this appliance to
1
/
2
" gas line.
3. After completing gas line connection, purge air from
gas line and test all gas joints from the gas meter to
the fireplace for leaks. Use a soap and water solution
or a gas sniffer.
4. To adjust flame height, turn HI/LO knob to HI to get
maximum pressure to burner. Turn HI/LO knob to LO
to get minimum pressure.
5. To check gas pressures at valve, turn captured screw
counter clockwise 2 or 3 turns and then place tubing
to pressure gauge over test point. Turn unit to high.
See Figure 20.
After taking pressure reading, be sure
and turn captured screw clockwise firmly to reseal. Do
not over torque. Check test points for gas leaks with a
soap and water solution.
Do not use open flame to check for
gas leaks.
W
A
R
N
IN
G
Figure 20 - Gas Pressure Check at Gas Valve
Pressure
Test “IN”
Pressure
Test “OUT”
HI/LO
Knob
Pilot Adjustment
Screw